1.
Ann Biomed Eng ; 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38619723

RESUMO

Airway distensibility is defined as the ease whereby airways are dilating in response to inflating lung pressure. If measured swiftly and accurately, airway distensibility would be a useful readout to parse the various elements contributing to airway wall stiffening, such as smooth muscle contraction, surface tension, and airway remodeling. The goal of the present study was to develop a method for measuring airway distensibility in mice. Lungs of BALB/c and C57BL/6 mice from either sex were subjected to stepwise changes in pressure. At each pressure step, an oscillometric perturbation was used to measure the impedance spectrum, on which the constant-phase model was fitted to deduce a surrogate for airway caliber called Newtonian conductance (GN). The change in GN over the change in pressure was subsequently used as an index of airway distensibility. An additional group of mice was infused with methacholine to confirm that smooth muscle contraction changes airway distensibility. GN increased with increasing steps in pressure, suggesting that the extent to which this occurs can be used as an index of airway distensibility. Airway distensibility was greater in BALB/c than C57BL/6 mice, and its variation by sex was mouse strain dependent, being greater in female than male in BALB/c mice with an inverse trend in C57BL/6 mice. Airway distensibility was also decreased by methacholine. This novel method swiftly measures airway distensibility in mice. Airway distensibility was also shown to vary with sex and mouse strain and to be sensitive to the contraction of smooth muscle.

2.
Sci Rep ; 14(1): 6278, 2024 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-38491110

RESUMO

Concerns are repeatedly raised about possible adverse respiratory effects of wearing filtering face pieces (FFP) during physical activity. This study compared the impact of FFP type 2 (NF95) on pulmonary function, blood gas values, metabolism and discomfort during light, moderate and vigorous physical activity. Healthy adults (n = 13; 6 females, 7 males; mean 31.3, SD 5.5 years) participated in this randomized two-armed (Ergometer cycling with a FFP type 2 vs. no mask) crossover trial. Baseline cardiopulmonary exercise testing and two interventions (masked and unmasked ergometer cycling 40%, 50% and 70% VO2max, 10 min each) were separated by 48 h washout periods. Spiroergometric data (End tidal carbon dioxide partial pressure PetCO2; breathing frequency; inspiration time), blood gas analysis outcomes (capillary carbon dioxide partial pressure, pCO2) and subjective response (Breathing effort and perceived exertion) were contrasted between conditions using ANOVAs. All participants completed the crossover trial, seven started with the FFP2 condition (No adverse events or side effects). FFP2 decreased breathing frequency, prolonged inspiration time, increased perceived breathing effort and PetCO2 (p < .05). Blood pCO2 in millimetres mercury increased during exercise with 50%VO2max (mean 36.67, SD 3.19 vs. mean 38.46, SD 2.57; p < .05) and 70%VO2max (35.04, 2.84 vs. 38.17, 3.43; p < .05) but not during exercise with 40%VO2max (36.55, 2.73 vs. 38.70). Perceived exertion was not affected (p > 0.05) by mask wearing. Conclusion: Mask-induced breathing resistance decreased respiratory performance and limited pulmonary gas exchange. While FFP2 affected subjective breathing effort per se, invasive diagnostics showed that statistically significant metabolic effects are induced from moderate intensity upwards. Trial registration: DRKS-ID: DRKS00030181, Date of registration: 05/09/2022 (German Register for Clinical Trials).


Assuntos
Dióxido de Carbono , Exercício Físico , Masculino , Adulto , Feminino , Humanos , Exercício Físico/fisiologia , Respiração , Pulmão , Consumo de Oxigênio
3.
Immun Inflamm Dis ; 12(3): e1225, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38533918

RESUMO

BACKGROUND: The dosage of ovalbumin (OVA) during the sensitization stage is considered a crucial factor in the development of airway hyperresponsiveness (AHR). However, the inconsistent dosages of sensitizing OVA used in current studies and the lack of research on their impact on AHR are notable limitations. METHODS: We examined the impact of increasing sensitizing doses of OVA in a murine asthma model, which entailed initial sensitization with OVA followed by repeated exposure to OVA aerosols. BALB/c mice were primed with doses of OVA (0, 10, 20, 50, and 100 µg) plus 1 mg Alum on Days 0 and 7, and were challenged with OVA aerosols (10 mg/mL for 30 min) between Days 14 and 17. Antigen-induced AHR to methacholine (MCh), as well as histological changes, eosinophilic infiltration, and epithelial injury were assessed. RESULTS: The result indicated that there are striking OVA dose-related differences in antigen-induced AHR to MCh. The most intense antigen-induced AHR to MCh was observed with sensitization at 50 µg, while weaker responses were seen at 10, 20, and 100 µg. Meanwhile, there was a significant increase in eosinophil count with sensitization at 50 µg. The changes of AHR were correlated with total cells count, lymphocytes count, eosinophils count, and basophils count in bronchoalveolar lavage fluid; however, it did not correlate with histological changes such as cellular infiltration into bronchovascular bundles and goblet cell hyperplasia of the bronchial epithelium. CONCLUSION: Overall, this study demonstrated that sensitization with 50 µg of OVA resulted in the most significant AHR compared to other dosages. These findings may offer valuable insights for future research on mouse asthma modeling protocols.


Assuntos
Asma , Hiper-Reatividade Brônquica , Hipersensibilidade Respiratória , Animais , Camundongos , Ovalbumina , Aerossóis e Gotículas Respiratórios , Asma/patologia , Cloreto de Metacolina
4.
Indian J Otolaryngol Head Neck Surg ; 76(1): 639-644, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38440564

RESUMO

Children with grade III or IV of adenotonsillar hypertrophy especially of a longer duration, may show cardiovascular changes due to mouth breathing. These changes can be detected on doppler echocardiocardiography which can be used as a screening tool. Fifty paediatric patients of grade 3 and 4 adenotonsillar hypertrophy underwent adenotonsillar resection after a pre-operative work up which included doppler echocardiography to measure pulmonary artery pressures. A post-operative doppler echocardiography was done after three months. 11 children (22%) showed deranged pulmonary artery pressure values with increased mean pulmonary artery pressure (MPAP) and pulmonary artery systolic pressure (PSAP) on preoperative doppler echocardiography, and 2 out of these 11 children had Pulmonary Artery Hypertension. A significant (p < 0.001) improvement was noted in pulmonary artery pressure values (MPAP and PSAP returned to normal) after adenotonsillectomy in 3-month postoperative echocardiography. Also, a statistically significant correlation was obtained between chronicity of symptoms and raised pulmonary artery pressures. Our study concluded that these children with chronic untreated upper airway obstructive symptoms get predisposed to potential cardiac complications. And these grave consequences can be easily prevented by a timely intervention.

5.
J Dent Sci ; 19(1): 329-337, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38303889

RESUMO

Background/purpose: This study was designed to explore upper airway aerodynamic characteristics in individuals diagnosed with obstructive sleep apnea (OSA) and to evaluate correlations between these characteristics and other anatomical upper airway findings in these patients. Materials and methods: This was a retrospective study of 40 OSA patients (22 male, 18 female) who were stratified into groups with mild, moderate, and severe disease based upon overnight polysomnographic (PSG) recording results. Newtom5G cone-beam CT scans (CBCT) were conducted for all patients, and the resultant images were used to reconstruct three-dimensional images of the upper airways which were used to calculate aerodynamic characteristics. Differences in these characteristics between groups were evaluated with one-way ANOVAs, while relationships between anatomical and aerodynamic characteristics were assessed through Pearson correlation analyses. Results: The aerodynamic of the upper airway has typical characteristic in severe group. There was a significant negative correlation in severe group between resistance during inspiration (Rin) and volume (V) (r = -0.693, P = 0.013), minimum axial area (MMA) (r = -0.685, P = 0.014), and lateral dimension (LAT) (r = -0.724, P = 0.008), resistance during expiration (Rex) and LAT (r = -0.923, P < 0.001). Conclusion: This study showed that airway resistance during inspiration and expiration are most closely associated with upper airway collapse in OSA patients, with repetitive collapse occurring during both of these breathing processes. LAT may be an important anatomical factor associated with OSA pathogenesis and treatment.

6.
Med Biol Eng Comput ; 62(2): 621-636, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37980307

RESUMO

We address the lack of research regarding aerodynamic events behind respiratory distress at COVID-19. The use of chest CT enables quantification of pneumonia extent; however, there is a paucity of data regarding the impact of airflow changes. We reviewed 31 COVID-19 patients who were admitted in March 2020 with varying severity of pulmonary disease. Lung volumes were segmented and measured on CT images and patient-specific models of the lungs were created. Incompressible, laminar, and three-dimensional Navier-Stokes equations were used for the fluid dynamics (CFD) analyses of ten patients (five mild, five pneumonia). Of 31 patients, 17 were female, 18 had pneumonia, and 2 were deceased. Effective lung volume decreased in the general group, but the involvement of the right lung was prominent in dyspnea patients. CFD analyses revealed that the mass flow distribution was significantly distorted in pneumonia cases with diminished flow rate towards the right lung. In addition, the distribution of flow parameters showed mild group had less airway resistance with higher velocity (1.228 m/s vs 1.572 m/s) and higher static pressure values at airway branches (1.5112 Pa vs 1.3024 Pa). Therefore, we conclude that airway resistance and mass flow rate distribution are as important as the radiological involvement degree in defining the disease severity.


Assuntos
COVID-19 , Imageamento Tridimensional , Feminino , Humanos , Masculino , Simulação por Computador , Hidrodinâmica , Imageamento Tridimensional/métodos , Pulmão/diagnóstico por imagem
7.
J Asthma ; 61(2): 132-139, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37594413

RESUMO

OBJECTIVES: Impulse oscillometry (IOS) can demonstrate small airways disease even when spirometry values are normal. However, it is unknown if the absence of symptoms excludes increased small airways resistance in asthma patients. We aimed to correlate symptoms (assessed through visual analogue scales) with measures of small airways resistance in patients with asthma and to determine whether less symptomatic patients have increased small airways resistance. METHODS: We conducted a single center, prospective cohort study. We included controlled asthma patients on as-needed inhaled corticosteroids-formoterol. Patients were evaluated on their symptom VASs, Spirometry and IOS (with R5-R20% measuring small airways resistance) which were measured both in periods when they were less symptomatic and symptomatic. Symptoms were assessed using MASK-air®, an mHealth app that includes a daily monitoring questionnaire with validated VASs. We correlated MASK-air VASs with small airways resistance. RESULTS: We assessed 29 patients. There was a significant correlation between VAS asthma and R5-R20% in symptomatic periods (r = 0.43; 95% CI = 0.13;0.68, p = 0.019), but not in less symptomatic periods (0.04; 95% CI-0.40;0.46; p = 0.825). In less symptomatic periods, patients presenting with low VAS asthma (VAS < 30) displayed a lower median R5-R20% than the remainder (0.26 versus 0.35), as well as a lower R5% (0.13 versus 0.15) (p < 0.001). In 68.9% of less symptomatic patients, R5-R20 values remained higher than normal values. CONCLUSION: In symptomatic patients on as-needed inhaled corticosteroids-formoterol, VAS asthma was associated with small airways resistance. However, even if these patients are less symptomatic, small airways resistance may be higher than normal. Since SAD significantly affects asthma control, patients should be carefully followed-up, even in less symptomatic periods.


Assuntos
Asma , Humanos , Asma/tratamento farmacológico , Asma/diagnóstico , Fumarato de Formoterol , Estudos Prospectivos , Escala Visual Analógica , Espirometria , Corticosteroides/uso terapêutico
8.
J Stomatol Oral Maxillofac Surg ; 125(4): 101708, 2023 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-38006945

RESUMO

OBJECTIVE: To ascertain the airway characteristics in patients with unilateral temporomandibular joint ankylosis and maxilla-mandibular deformities (UTMAMD) and investigate the potential risk factors associated with obstructive sleep apnea (OSA) among UTMAMD patients. METHODS: Authors conducted a retrospective single-center study to assess and compare study group consisting of a cohort of 32 patients diagnosed with UTMAMD between January 2011 and July 2022 with control group including 54 participants. The study group was further divided into two subgroups based on the presence or absence of OSA in patients. Parameters related to the upper airway were measured and analyzed using three-dimensional reconstruction of computed tomographic scans. The measurements of airway parameters were compared between study group and control group and between two subgroups. Pearson correlation analysis was used to identify the factors associated with the presence of OSA, and a multiple variable regression model was used to identify risk factors for OSA. RESULTS: Airway volume (VOL), Minimum cross-section area (min CSA), mean CSA, tilt in sagittal plane (TS), and tilt in sagittal plane (TC) in velopharynx; VOL, airway length (AL), min CSA, mean CSA, TS, TC, and airway deviation (AD) in glossopharynx; min CSA, TS, and AD in hypopharynx were found difference with significance between study group and control group. Lateral dimension/anterior-posterior dimension (LAT/AP) ratio in velopharynx and min CSA, TC, and LAT/AP ratio in glossopharynx were significant different between patients with UTMAMD with OSA and without OSA. CONCLUSIONS: The upper airway of patients with UTMAMD exhibits significant narrowing and distortion, rendering them susceptible to suffer from OSA. Patients with UTMAMD and OSA demonstrate more elliptical airways, and the glossopharyngeal LAT/AP ratio is a predictive indicator for the occurrence of OSA.

9.
Allergol Immunopathol (Madr) ; 51(6): 97-103, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37937502

RESUMO

OBJECTIVE: To investigate the effects of corilagin on inflammation and collagen deposition in ovalbumin (OVA)-induced asthma mouse model and uncover the mechanism. METHODS: We constructed a mouse model of OVA-induced asthma. Enzyme-linked-immunosorbent serologic assays were conducted to detect the effects of corilagin on cytokines and Immunoglobulin E (IgE) production. Hematoxylin and eosin staining was used to show pathological features in lung tissues. Masson trichrome assay was used to examine collagen deposition. In addition, the lung function was detected by mouse lung function apparatus. Immunoblot was used to confirm the mechanism. RESULTS: Corilagin alleviates OVA-induced cytokine and IgE production. In addition, corilagin alleviates OVA-induced pathological changes and collagen deposition in lung tissues. Corilagin also suppressed airway resistance and lung function in mice. Mechanically, corilagin activated the adenosine monophosphate-activated protein kinase (AMPK) pathway in lung tissues. CONCLUSION: Corilagin attenuates airway inflammation and collagen deposition in OVA-induced asthmatic mice via AMPK pathway.


Assuntos
Proteínas Quinases Ativadas por AMP , Asma , Animais , Camundongos , Ovalbumina , Proteínas Quinases Ativadas por AMP/metabolismo , Proteínas Quinases Ativadas por AMP/farmacologia , Líquido da Lavagem Broncoalveolar , Pulmão/patologia , Inflamação/patologia , Citocinas/metabolismo , Colágeno/efeitos adversos , Colágeno/metabolismo , Imunoglobulina E/metabolismo , Camundongos Endogâmicos BALB C , Modelos Animais de Doenças
10.
Laryngoscope Investig Otolaryngol ; 8(5): 1136-1145, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37899860

RESUMO

Objectives: Anterior active rhinomanometry (AAR) is widely used in Swedish routine clinical practice to decide if septoplasty is necessary. The scientific basis for the method needs to be strengthened. Therefore, the aims were to evaluate nasal airway resistance (NAR), paradoxical reactions to pharmacological decongestion, and test-retest characteristics of the Rhino-Comp® AAR in healthy subjects. Methods: A prospective longitudinal design was used. AAR was performed before and after decongestion at baseline and after ≥6 months on 60 healthy volunteers. The relationships between NAR, height, weight, BMI, sex, and allergic rhinitis were evaluated by regression analyses. Descriptive statistics were used to evaluate paradoxical reactions. Test-retest and repeatability characteristics were evaluated with intra-class coefficients (ICC), Cronbach's α, and standard error of measurement. Results: No statistically significant differences were found between genders or nasal cavity sides. NAR was statistically significantly related to height. Short- and long-term test-retest characteristics were good with ICC and Cronbach's α > .75. The minimal significant difference in NAR Log10V2 values between the two measurements was 0.11 and 0.09 (long- and short-term). Paradoxical reactions to pharmacological decongestion were rare, mostly weak, and not evidently reproducible. Conclusion: In this study, we report reference data for healthy subjects, test-retest capabilities, and the minimal relevant difference between two measurements for the Rhino-Comp® AAR, information that is vital and necessary for the appropriate use of AAR in clinical practice. An effective method for pharmacological decongestion is described and recommended for future studies and clinical practice. Paradoxical reactions to pharmacological decongestants exist but maybe without clinical significance. Level of Evidence: NA.

11.
Cureus ; 15(9): e45185, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37842344

RESUMO

BACKGROUND: Noninvasive positive pressure ventilation (NIPPV) maintains mean airway pressures well, and its usability for preoxygenation is well described. Anesthesia machine-delivered NIPPV-based preoxygenation has recently been evaluated against the traditional manual bag-mask ventilation (BMV). The efficiency of such a technique over the traditional one is yet to be established well. The present study evaluated the feasibility of machine-delivered preoxygenation using pressure support ventilation (PSV) with positive end-expiratory pressure (PEEP) and compared the effectiveness with BMV. METHODS: Thirty overweight and obese adults belonging to the American Society of Anesthesiologist's physical status I-II were randomized to receive PSV+PEEP or BMV for preintubation preoxygenation targeted to a fraction of expired oxygen (FeO2) of 85% and 90% or for a maximum period of five minutes, whichever came first. Postintubation, the patient was observed for the time taken until 1% desaturation without ventilation. Arterial blood gases, respiratory variables, FeO2 achieved, and different times were collected and compared. RESULTS: The baseline characteristics and arterial blood gases were similar between the two groups. The PSV+PEEP group had consistent and favorable tidal volume and airway pressure delivery. The difference in time to reach a FeO2 of 85% between the two groups was not statistically different. Only two patients achieved a FeO2 of 90% in the PSV+PEEP group versus none in the BMV group. However, partial pressure of oxygen at 1% desaturation (217.42±109.47 versus 138.073±71.319 mmHg, p 0.0259) was higher in the PSV+PEEP group. Similarly, the time until 1% desaturation was significantly prolonged in the PSV+PEEP group (206.6±76.952 versus 140.466±54.245 seconds, p 0.0111). CONCLUSION: The present pilot study findings indicate that preintubation machine-delivered PSV+PEEP-based preoxygenation is feasible and might be more effective than traditional BMV in overweight and obese patients.

12.
Zhongguo Yi Liao Qi Xie Za Zhi ; 47(5): 528-532, 2023 Sep 30.
Artigo em Chinês | MEDLINE | ID: mdl-37753892

RESUMO

In order to solve the problems of quality control and traceability of medical test lung for meeting the calibration conditions of JJF 1234-2018 Calibration Specification for Ventilators, the calibration device and method are researched for compliance and airway resistance of medical test lung in this paper. A calibration device for medical test lung is designed using constant volume active piston technology to simulate human breathing. Through comparison experiment, the deviation between this device and the similar foreign device can be found. The deviation is lower than 0.4% for lung compliance and lower than 0.7% for airway resistance. The calibration of lung compliance and airway resistance can be completed by this device. This device has a clear and complete traceability path to ensure quality control from the source. The calibration of ventilator is improved. This paper provides a reference for related metrology departments and medical institutions to study on quality inspection of respiratory medical instruments.


Assuntos
Respiração , Ventiladores Mecânicos , Humanos , Calibragem , Controle de Qualidade , Pulmão
13.
J Clin Med ; 12(18)2023 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-37762913

RESUMO

Obstructive sleep apnea (OSA) during pregnancy can negatively affect both the mother and the baby. Our main goal is to show whether there is an association between OSA during pregnancy and delivering small for gestational age (SGA) infants. This systematic review was conducted according to the PRISMA 2020 statement using three databases: MEDLINE via PubMed, Scopus, and Cochrane Library. All databases were last accessed on 1 June 2023. The implemented systematic literature search identified 744 articles. After excluding reviews, meta-analyses, book chapters, case reports, and letters, 47 studies were analyzed, 18 of which finally met the inclusion criteria. The included studies mainly indicate that OSA during pregnancy may not significantly impact SGA, but some of them have shown the existence of this relation. Nevertheless, it is recommended that all pregnant women should be screened for symptoms of OSA and that sleep tests should be performed on those who show signs of it. Detecting and treating OSA early in pregnancy can help reduce the condition's negative effects. However, more extensive studies are still needed to gather clear evidence on the impact of an OSA diagnosis on mothers and babies.

14.
Allergol Immunopathol (Madr) ; 51(4): 175-181, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37422795

RESUMO

BACKGROUND: Asthma is a common lung disease with increasing incidence and prevalence globally, thereby imposing a substantial global health and economic burden. Recently, studies have shown that Mitsugumin 53 (MG53) exhibits multiple biological functions and plays a protective role in a variety of diseases. However, the role of MG53 in asthma remained unknown; hence, in the present study we aimed to explore the functioning of MG53 in asthma. METHODS: Using ovalbumin and aluminum hydroxide adjuvant, an OVA-induced asthmatic animal model was constructed and administered with MG53. After establishing mice model, inflammatory cell counts and the levels of type 2 inflammatory cytokines were examined and histological staining of lung tissues were performed. The levels of key factors associated with the nuclear factor-κB (NF-κB) pathway were detected. RESULTS: Asthmatic mice displayed a remarkable accumulation of white blood cells, neutrophils, macrophages, lymphocytes, and eosinophils in bronchoalveolar lavage fluid, compared to control mice. MG53 treatment lowered the number of these inflammatory cells in asthmatic mice. The level of type 2 cytokines in asthmatic mice was higher than that in control mice, and was lessened by MG53 intervention. In asthmatic mice, airway resistance was elevated, which was reduced by MG53 treatment. In addition, inflammatory cell infiltration and mucus secretion were aggravated in the lung tissues of asthmatic mice, and both were attenuated by MG53 intervention. The levels of phosphorylated p65 and phosphorylated inhibitor of nuclear factor kappa-B kinase were elevated in asthmatic mice, but were downregulated by MG53 supplement. CONCLUSION: The aggravated airway inflammation was observed in asthmatic mice; however, MG53 treatment suppressed airway inflammation by targeting the NF-κB pathway.


Assuntos
Asma , NF-kappa B , Camundongos , Animais , NF-kappa B/metabolismo , Pulmão/patologia , Líquido da Lavagem Broncoalveolar , Inflamação/patologia , Citocinas/metabolismo , Camundongos Endogâmicos BALB C , Ovalbumina , Modelos Animais de Doenças , Proteínas de Membrana/metabolismo
15.
Lung ; 201(4): 371-379, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37421433

RESUMO

PURPOSE: Respiratory mechanics and the role of sex hormones in pregnancy are not well elucidated. We examined longitudinal and positional changes in lung mechanics in pregnancy and investigated the role of sex hormones. METHODS: A longitudinal study enrolled 135 women with obesity in early pregnancy. Fifty-nine percent of women identified as White; median body mass index at enrollment was 34.4 kg/m2. Women with respiratory disease were excluded. We obtained measurements of airway resistance and respiratory system reactance in various positions using impedance oscillometry and sex hormones in early and late pregnancy. RESULTS: With pregnancy progression, there was a significant increase in resonant frequency (Fres) (p = 0.012), integrated area of low frequency reactance (AX) (p = 0.0012) and R5-R20Hz (p = 0.038) in the seated position, and a significant increase in R5Hz (p = 0.000), Fres (p = 0.001), AX (p < 0.001 = 0.000), and R5-R20Hz (p = 0.014) in the supine position. Compared to the seated position, the supine position was associated with a significant increase in R5Hz, R20Hz, X5Hz, Fres, and AX in early (p-values < 0.026) and late pregnancy (p-values ≤ 0.001). Changes in progesterone levels between early and late pregnancy predicted the change in R5, Fres, and AX (p-values ≤ 0.043). CONCLUSION: Resistive and elastic loads increase with pregnancy progression and a change in body position from seated to supine increases resistive and elastic loads in both early and late pregnancies. The increase in airway resistance is primarily related to an increase in peripheral rather than central airways resistance. There was an association between the change in progesterone levels and airway resistance.


Assuntos
Sobrepeso , Gestantes , Humanos , Feminino , Gravidez , Sobrepeso/complicações , Estudos Longitudinais , Progesterona , Pulmão , Resistência das Vias Respiratórias , Mecânica Respiratória , Obesidade/complicações , Espirometria
16.
J Biomech ; 157: 111713, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37413823

RESUMO

Infection with COVID-19 can cause severe complication in the respiratory system, which may be related to increased respiratory resistance. Computational fluid dynamics(CFD) was used in this study to calculate the airway resistance based on the airway anatomy and a common air flowrate. The correlation between airway resistance and COVID-19 prognosis was then investigated. A total of 23 COVID-19 patients with 54 CT scans were grouped into the good prognosis and bad prognosis group based on whether the CT scan shows significant decrease in the pneumonia volume after one week treatment and retrospectively analyzed. A baseline group of 8 healthy people with the same age and gender ratio is enrolled for comparison. Results show that the airway resistance at admission is significantly higher for COVID-19 patients with poor prognosis than those with good prognosis and the baseline(0.063 ± 0.055 vs 0.029 ± 0.011 vs 0.017 ± 0.006 Pa/(ml/s),p = 0.01). In the left superior lobe (r = 0.3974,p = 0.01),left inferior lobe (r = 0.4843,p < 0.01), the right inferior lobe (r = 0.5298,p < 0.0001), the airway resistance was significantly correlated with the degree of pneumonia infection. It is concluded that for COVID-19 patients', airway resistance at admission is closely associated with their prognosis, and has the clinical potential to be used as an index for patients' diagnosis.


Assuntos
Resistência das Vias Respiratórias , COVID-19 , Humanos , Estudos Retrospectivos , Hidrodinâmica , Pulmão/diagnóstico por imagem
18.
Int J Chron Obstruct Pulmon Dis ; 18: 995-1002, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37260547

RESUMO

Background: The pharmacological association umeclidinium/vilanterol (UMEC/VI) allows to implement a very effective dual bronchodilation in chronic obstructive pulmonary disease (COPD), thus optimizing bronchodilating therapy. Methods: The main purpose of our real-world observational study was to evaluate in COPD patients the effects of UMEC/VI on lung function and respiratory symptoms. Functional and clinical parameters were assessed at baseline, and after 52 weeks of treatment with this combined double inhaled therapy. Results: We enrolled 110 subjects suffering from COPD. A 12-month UMEC/VI treatment induced significant improvements in total lung capacity (TLC) (p < 0.05), and residual volume (RV) (p < 0.0001). Pulmonary deflation was paralleled by significant increases of forced expiratory volume in one second (FEV1) (p < 0.0001), forced vital capacity (FVC) (p < 0.01), forced expiratory flow between 25% and 75% of FVC (FEF25-75) (p < 0.0001) and diffusion capacity of the lung (DLCOcSB) (p < 0.05). In addition, in the same period, we also observed significant reductions of airway resistance including total resistance (Rtot) (p < 0.0001) and specific effective resistance (sReff) (p < 0.0001). Other improvements were detected with regard to modified British Medical Research Council (mMRC) questionnaire score (p < 0.0001), COPD Assessment Test (CAT) score (p < 0.0001), and COPD exacerbation rate (p < 0.0001). In particular, the reported changes of mMRC/CAT scores and COPD exacerbation numbers were significantly correlated with UMEC/VI-induced modifications of TLC, RV, FVC and FEV1. Conclusion: In conclusion, our study corroborates in a real-life context the effectiveness of UMEC/VI in COPD treatment. Indeed, our broad investigational strategy has allowed to better characterize the functional mechanisms underpinning the therapeutic properties of UMEC/VI association.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Humanos , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Broncodilatadores , Resultado do Tratamento , Antagonistas Muscarínicos , Combinação de Medicamentos , Administração por Inalação , Álcoois Benzílicos , Clorobenzenos , Quinuclidinas , Método Duplo-Cego
19.
Eur J Med Res ; 28(1): 195, 2023 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-37355638

RESUMO

BACKGROUND: Respiratory mechanics monitoring provides useful information for guiding mechanical ventilation, but many measuring methods are inappropriate for awake patients. This study aimed to evaluate the accuracy of dynamic mechanics estimation using expiratory time constant (RCexp) calculation during noninvasive pressure support ventilation (PSV) with air leak in different lung models. METHODS: A Respironics V60 ventilator was connected to an active breathing simulator for modeling five profiles: normal adult, restrictive, mildly and severely obstructive, and mixed obstructive/restrictive. Inspiratory pressure support was adjusted to maintain tidal volumes (VT), achieving 5.0, 7.0, and 10.0 ml/kg body weight. PEEP was set at 5 cmH2O, and the back-up rate was 10 bpm. Measurements were conducted at system leaks of 25-28 L/min. RCexp was estimated from the ratio at 75% exhaled VT and flow rate, which was then used to determine respiratory system compliance (Crs) and airway resistance (Raw). RESULTS: In non-obstructive conditions (Raw ≤ 10 cmH2O/L/s), the Crs was overestimated in the PSV mode. Peak inspiratory and expiratory flow and VT increased with PS levels, as calculated Crs decreased. In passive breathing, the difference of Crs between different VT was no significant. Underestimations of inspiratory resistance and expiratory resistance were observed at VT of 5.0 ml/kg. The difference was minimal at VT of 7.0 ml/kg. During non-invasive PSV, the estimation of airway resistance with the RCexp method was accurately at VT of 7.0 ml/kg. CONCLUSIONS: The difference between the calculated Crs and the preset value was influenced by the volume, status and inspiratory effort in spontaneously breathing.


Assuntos
Pulmão , Respiração Artificial , Adulto , Humanos , Respiração Artificial/métodos , Respiração com Pressão Positiva/métodos , Mecânica Respiratória , Ventiladores Mecânicos
20.
Diving Hyperb Med ; 53(2): 129-137, 2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37365130

RESUMO

INTRODUCTION: The performance of the Shangrila590 hyperbaric ventilator (Beijing Aeonmed Company, Beijing, China) was evaluated during volume-controlled ventilation. METHODS: Experiments were conducted in a multiplace hyperbaric chamber at 101, 152, 203, and 284 kPa (1.0, 1.5, 2.0 and 2.8 atmospheres absolute [atm abs]). With the ventilator in volume control ventilation (VCV) mode and connected to a test lung, comparison was made of the set tidal volume (VTset) versus delivered tidal volume (VT) and minute volume (MV) at VTset between 400 and 1,000 mL. Peak inspiratory pressure was also recorded. All measurements were made across 20 respiratory cycles. RESULTS: Across all ambient pressures and ventilator settings the difference between VTset and actual VT and between predicted MV and actual MV were small and clinicially insignificant despite reaching statistical significance. Predictably, Ppeak increased at higher ambient pressures. With VTset 1,000 mL at 2.8 atm abs the ventilator produced significantly greater VT, MV and Ppeak. CONCLUSIONS: This new ventilator designed for use in hyperbaric environments performs well. It provides relatively stable VT and MV during VCV with VTset from 400 mL to 800 mL at ambient pressures from 1.0 to 2.8 atm abs, as well as VTset 1,000 mL at ambient pressures from 1.0 to 2.0 atm abs.


Assuntos
Oxigenoterapia Hiperbárica , Humanos , Ventiladores Mecânicos , Volume de Ventilação Pulmonar , Pulmão , Oxigênio , Respiração Artificial